SAFETY DATA SHEET

(in accordance with Regulation (EU) 2020/878)
GG-GF-1234YF Kryon HFO-1234YF (R- 1234YF)
Source header as printed:Version 1Date of compilation: 04/05/2026Version 2 (replaces version 1)Print date: 04/05/2026
ROGLA distributor reference edition

Distributor edition of ROGLA GmbH (distributor). Basis: supplier's English safety data sheet GG-GF-1234YF, Kryon HFO-1234YF (R-1234YF), as received; text reproduced unchanged. ROGLA did not compile or certify the technical content.

Document language: English – original source text; only the reseller's logo and contact block were replaced by ROGLA (distributor).

Not a final reviewed release: not checked by a qualified person. ROGLA GmbH is the distributor, not the manufacturer or author of the technical content, which is taken unchanged from the source; inconsistencies in the source have not been corrected.

Covers the product Kryon HFO-1234YF. That it matches the R1234yf offered is not confirmed. Section 1.4 (emergency telephone number) is missing from the source; the source names neither manufacturer nor compiler.

Questions about this document: info@rogla-gmbh.de

Product identity not yet confirmed: this sheet covers the Kryon brand product named above. That it is the R1234yf supplied by ROGLA has not been confirmed (an identical CAS number alone is not proof).

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING.

1.1 Product identifier.

Product Name:GG-GF-1234YF Kryon HFO-1234YF (R-1234YF)
Chemical Name:2,3,3,3-tetrafluoroprop-1-ene
CAS No:754-12-1
EC No:468-710-7
Registration No:01-0000019665-61-XXXX

1.2 Relevant identified uses of the substance or mixture and uses advised against.

for professional and industrial use only

Uses advised against:

Uses other than those recommended.

1.3 Details of the supplier of the safety data sheet.

ROGLA GmbH
Siemensstraße 5, 59199 Bönen, Germany
T +49 151 67605803
info@rogla-gmbh.de
(distributor / distributor edition)

1.4 Emergency telephone number. [not contained in the source]

ROGLA note: the supplier's sheet contains no section 1.4 and no emergency telephone number. No supplier number or advisory service has been invented or added; this point remains open.

ROGLA note (added, not part of the source): In an immediate emergency in the EU, call 112 (ambulance, fire brigade, police). General emergency number; it is not a chemical information service and does not replace the emergency telephone number missing from section 1.4 of the source. (Source: European Union (europa.eu): https://europa.eu/youreurope/citizens/travel/security-and-emergencies/emergency/index_en.htm)

SECTION 2: HAZARDS IDENTIFICATION.

2.1 Classification of the substance or mixture.

In accordance with Regulation (EC) No 1272/2008:

Flam. Gas 1B :Flammable gas.
Press. Gas :Contains gas under pressure; may explode if heated.

2.2 Label elements.

Labelling in accordance with Regulation (EC) No 1272/2008:

Pictograms:

GHS02GHS04

Signal Word:

Danger

Hazard statements:

H221Flammable gas.
H280Contains gas under pressure; may explode if heated.

Precautionary statements:

P210Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P377Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
P381In case of leakage, eliminate all ignition sources.
P403Store in a well-ventilated place.
P410+P403Protect from sunlight. Store in a well-ventilated place.

2.3 Other hazards.

The substance is not PBT

The substance is not vPvB

Substance does not have endocrine disrupting properties.

In normal use conditions and in its original form, the product itself does not involve any other risk for health and the environment.

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS.

3.1 Substances.

Mono-constituent.

IdentifiersNameConcentrate(*)Classification - Regulation (EC) No 1272/2008
ClassificationSpecifics concentration limits and Acute toxicity estimate
: 754-12-1
: 468-710-7
2,3,3,3-tetrafluoroprop-1-ene100%%Flam. Gas 1B,
H221
Flam. Gas 1A,
H220:
6,2%<C<12,3 %

3.2 Mixtures.

Not applicable.

SECTION 4: FIRST AID MEASURES.

4.1 Description of first aid measures.

It is recommended to move the affected person out of the exposure area.

Inhalation.

It may cause asphyxia at high concentrations. Asphyxia can lead to loss of consciousness or mobility. Take the victim into open air; keep them warm and calm. If breathing is irregular or stops, perform artificial respiration.

Eye contact.

Remove contact lenses, if present and if it is easy to do. Wash eyes with plenty of clean and cool water for at least 10 minutes while pulling eyelids up, and seek medical assistance.

Skin contact.

Do not rub affected areas. Wash skin vigorously with water and soap or a suitable skin cleaner. NEVER use solvents or thinners.

Ingestion.

This route of exposure is unlikely.

4.2 Most important symptoms and effects, both acute and delayed.

No known acute or delayed effects from exposure to the product.

4.3 Indication of any immediate medical attention and special treatment needed.

Request immediate medical attention. If respiratory and/or heart failure occurs, perform resuscitation manoeuvres. Never administer anything orally to persons who are unconscious. If the person vomits, clear the respiratory tract.

SECTION 5: FIREFIGHTING MEASURES.

In case of fire, as a general hazard, heat can cause containers to explode.

The product is Extremely inflammable, it can cause or considerably worsen a fire, the necessary prevention measures should be taken and risks avoided. In case of fire, the following measures are recommended:

5.1 Extinguishing media.

Suitable extinguishing media:

Extinguisher powder or CO2.

Unsuitable extinguishing media:

Do not use a direct stream of water to extinguish. In the presence of electrical voltage, you cannot use water or foam as extinguishing media.

5.2 Special hazards arising from the substance or mixture.

Special risks.

Exposure to combustion or decomposition products can be harmful to your health.

During a fire and depending on its magnitude the following may occur:

- Flammable vapors or gases.

- Explosions.

5.3 Advice for firefighters.

Use water to cool tanks, cisterns, or containers close to the heat source or fire. Take wind direction into account. Prevent the products used to fight the fire from going into drains, sewers, or waterways. Follow the instructions given in the emergency or fire evacuation plan or plans if available. Move containers away from the area if there is no danger in doing so. Keep away from containers and continue cooling them from a safe place. Stop the leak if this can be done safely and do not put out fire until the leak has been closed off. If it is not possible to keep the fire under control, leave the area and let it burn.

Fire protection equipment.

According to the size of the fire, it may be necessary to use protective suits against the heat, individual breathing equipment, gloves, protective goggles or facemasks, and boots. During extinction and depending on the magnitude and proximity to the fire, additional protective equipment such as chemical protection gloves, heat-reflecting suits or gas-tight suits may be required.

SECTION 6: ACCIDENTAL RELEASE MEASURES.

6.1 Personal precautions, protective equipment and emergency procedures.

Eliminate possible ignition points and ventilate the area. No smoking. Avoid breathing fumes. Isolate the area and ensure adequate ventilation. Stockpiling in basements, pits or any confined space or depressed area can be hazardous. Use a self-contained breathing apparatus when the atmosphere is not suitable to be breathed. For exposure control and individual protection measures, see section 8.

6.2 Environmental precautions.

Product not classified as hazardous for the environment, avoid spillage as much as possible.

6.3 Methods and material for containment and cleaning up.

Use soapsuds to detect small leaks. Stop the leak if this can be done safely. Ensure adequate ventilation to prevent the accumulation of gases or vapours.

En caso de que el gas condense:

Contain and collect spillage with inert absorbent material (earth, sand, vermiculite, Kieselguhr...) and clean the area immediately with a suitable decontaminant. Deposit waste in closed and suitable containers for disposal, in compliance with local and national regulations (see section 13).

6.4 Reference to other sections.

For exposure control and individual protection measures, see section 8.

For later elimination of waste, follow the recommendations under section 13.

SECTION 7: HANDLING AND STORAGE.

7.1 Precautions for safe handling.

The fumes are heavier than air and can spread across the ground. They can form explosive mixtures with air. Prevent the creation of flammable or explosive fume concentrations in the air; prevent fume concentrations above work exposure limits. The product must only be used in areas where all unprotected flames and other ignition points have been eliminated. Electrical equipment has to be protected according to applicable standards.

The product can be electrostatically charged: always use earth grounds when transferring the product. Operators must use anti-static footwear and clothing, and floors must be conductors.

Keep the container tightly closed and isolated from heat sources, sparks, and fire. Do not use tools that can cause sparks. For personal protection, see section 8.

In the application area, smoking, eating, and drinking must be prohibited.

Follow legislation on occupational health and safety.

Pressurised gases must be handled by suitably trained and experienced individuals. Use equipment suitable for supply pressure and temperature. Protect containers against physical damage and keep valves clean and in perfect condition. Do not tamper with original packaging.

7.2 Conditions for safe storage, including any incompatibilities.

Store according to local legislation. Observe indications on the label. Store the containers between 5 and 25 º C, in a dry and well-ventilated place, far from sources of heat and direct solar light. Keep far away from ignition points. Keep away from oxidising agents and from highly acidic or alkaline materials. Do not smoke. Prevent the entry of non-authorised persons. It must not be stored under conditions conducive to corrosion of the container. Protect containers against physical damage and inspect them regularly to ensure they are in good condition.

Classification and threshold amount of storage in accordance with Annex I to Directive 2012/18/EU (SEVESO III):

CodeDescriptionQualifying quantity (tonnes) for the application of
Lower-tier requirementsUpper-tier requirements
P2FLAMMABLE GASES1050

7.3 Specific end use(s).

Not available.

SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION.

8.1 Control parameters.

The product does NOT contain substances with Professional Exposure Environmental Limit Values.The product does NOT contain substances with Biological Limit Values.

8.2 Exposure controls.

Measures of a technical nature:

Provide adequate ventilation, which can be achieved by using good local exhaust-ventilation and a good general exhaust system.

Concentration:100 %
Uses:for professional and industrial use only
Breathing protection
Breathing protection:
PPE:Filter mask for protection against gases and particles.
Characteristics:«CE» marking, category III. The mask must have a wide field of vision and an anatomically designed form in order to be sealed and watertight.
CEN standards:EN 136, EN 140, EN 405
Maintenance:Should not be stored in places exposed to high temperatures and damp environments before use. Special attention should be paid to the state of the inhalation and exhalation valves in the face adaptor.
Observations:Read carefully the manufacturer's instructions regarding the equipment's use and maintenance. Attach the necessary filters to the equipment according to the specific nature of the risk (Particles and aerosols: P1-P2-P3, Gases and vapours: A-B-E-K-AX), changing them as advised by the manufacturer.
Filter Type needed:A2
Hand protection
Hand protection:
PPE:Protective gloves against mechanical risks
Characteristics:«CE» marking, category II.
CEN standards:EN 420, EN 388, EN 374-1, EN 374-2, EN 374-3
Maintenance:Keep in a dry place, away from any sources of heat, and avoid exposure to sunlight as much as possible. Do not make any changes to the gloves that may alter their resistance, or apply paints, solvents or adhesives. The gloves, whether new or used, must be carefully inspected before use, particularly after a cleaning treatment and before putting them on, to ensure that there is no damage present. The gloves must not be left in contaminated conditions if they are to be reused, in which case the gloves must be cleaned as much as possible, provided there is no danger, before taking them off.
Observations:Gloves should be of the appropriate size and fit the user's hand well, not being too loose or too tight. Always use with clean, dry hands.
Material:PVC (polyvinyl chloride)
Breakthrough time (min.):> 480
Material thickness (mm):0,35
Eye protection
Eye protection:
PPE:Face shield.
Characteristics:«CE» marking, category II. Face and eye protector against splashing liquid.
CEN standards:EN 165, EN 166, EN 167, EN 168
Maintenance:Visibility through lenses should be ideal. Therefore, these parts should be cleaned daily. Protectors should be disinfected periodically following the manufacturer's instructions. Make sure that mobile parts move smoothly.
Observations:Face shields should offer a field of vision with a dimension in the central line of, at least, 150 mm vertically once attached to the frame.
Skin protection:
PPE:Protective clothing.
Characteristics:«CE» marking, category II. Protective clothing should not be too tight or loose in order not to obstruct the user's movements.
CEN standards:EN 340
Maintenance:In order to guarantee uniform protection, follow the washing and maintenance instructions provided by the manufacturer.
Observations:The protective clothing should offer a level of comfort in line with the level of protection provided in terms of the hazard against which it protects, bearing in mind environmental conditions, the user's level of activity and the expected time of use.
PPE:Work footwear.
Characteristics:«CE» marking, category II.
CEN standards:EN ISO 13287, EN 20347
Maintenance:This product adapts to the first user's foot shape. That is why, as well as for hygienic reasons, it should not be used by other people.
Observations:Work footwear for professional use includes protection elements aimed at protecting users against any injury resulting from an accident

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES.

9.1 Information on basic physical and chemical properties.

Physical state:Gas - compressed
Colour:Not applicable/Not available due to the nature/properties of the product
Odour:Not applicable/Not available due to the nature/properties of the product
Odour threshold:Not applicable/Not available due to the nature/properties of the product
Melting point:Not applicable/Not available due to the nature/properties of the product
Freezing point:Not applicable/Not available due to the nature/properties of the product
Boiling point or initial boiling point and boiling range:-29 ºC
Flammability:Not applicable/Not available due to the nature/properties of the product
Lower explosion limit:Not applicable/Not available due to the nature/properties of the product
Upper explosion limit:Not applicable/Not available due to the nature/properties of the product
Flash point:Not applicable/Not available due to the nature/properties of the product
Auto-ignition temperature:Not applicable/Not available due to the nature/properties of the product
Decomposition temperature:Not applicable/Not available due to the nature/properties of the product
pH:Not available (Substance/mixture is a gas).
Kinematic viscosity:Not applicable/Not available due to the nature/properties of the product
Solubility:Not applicable/Not available due to the nature/properties of the product
Hydrosolubility:Not applicable/Not available due to the nature/properties of the product
Liposolubility:Not applicable/Not available due to the nature/properties of the product
Partition coefficient n-octanol/water (log value):Not applicable/Not available due to the nature/properties of the product
Vapour pressure:Not applicable/Not available due to the nature/properties of the product
Absolute density:0,96
Relative density:Not applicable/Not available due to the nature/properties of the product
Relative vapour density:Not applicable/Not available due to the nature/properties of the product
Particle characteristics:Not applicable/Not available due to the nature/properties of the product

9.2 Other information

Not applicable/Not available due to the nature/properties of the product

SECTION 10: STABILITY AND REACTIVITY.

10.1 Reactivity.

The product does not present hazards by their reactivity.

10.2 Chemical stability.

Stable under the recommended handling and storage conditions (see section 7).

10.3 Possibility of hazardous reactions.

Contains gas under pressure; may explode if heated.

10.4 Conditions to avoid.

Avoid any improper handling.

10.5 Incompatible materials.

Keep away from oxidising agents and from highly alkaline or acidic materials in order to prevent exothermic reactions.

10.6 Hazardous decomposition products.

No decomposition if used for the intended uses.

SECTION 11: TOXICOLOGICAL INFORMATION.

11.1 Information on hazard classes as defined in Regulation (EC) Nº 1272/2008.

There are no tested data available on the product.

a) acute toxicity;

Not conclusive data for classification.

b) skin corrosion/irritation;

Not conclusive data for classification.

c) serious eye damage/irritation;

Not conclusive data for classification.

d) respiratory or skin sensitisation;

Not conclusive data for classification.

e) germ cell mutagenicity;

Not conclusive data for classification.

f) carcinogenicity;

Not conclusive data for classification.

g) reproductive toxicity;

Not conclusive data for classification.

h) STOT-single exposure;

Not conclusive data for classification.

i) STOT-repeated exposure;

Not conclusive data for classification.

j) aspiration hazard;

Not conclusive data for classification.

11.2 Information on other hazards.

Endocrine disrupting properties

This product does not contain components with endocrine-disrupting properties with effects on human health.

Other information

There is no information available on other adverse health effects.

SECTION 12: ECOLOGICAL INFORMATION.

12.1 Toxicity.

No information is available regarding the ecotoxicity.

12.2 Persistence and degradability.

No information is available regarding the biodegradability

No information is available on the degradability

No information is available about persistence and degradability of the product.

The product evaporates quickly and enters the gas phase at room temperature. Information on its persistence and degradability is not relevant.

12.3 Bioaccumulative potential.

No information is available regarding the bioaccumulation.

12.4 Mobility in soil.

No information is available about the mobility in soil.

Soil or water contamination is unlikely due to high volatility of the product.

12.5 Results of PBT and vPvB assessment.

No information is available about the results of PBT and vPvB assessment of the product.

12.6 Endocrine disrupting properties.

This product doesn't contain components with environmental endocrine disrupting properties.

12.7 Other adverse effects.

The product is not affected by the Regulation (EC) No 1005/2009 of the European Parliament and of the Council of 16 September 2009 on substances that deplete the ozone layer.

No information is available about other adverse effects for the environment.

SECTION 13: DISPOSAL CONSIDERATIONS.

13.1 Waste treatment methods.

Dispose of packaging through the supplier. Transport, unloading, treatment or disposal activities may be subject to additional local/national legislation. Waste and empty containers must be handled and eliminated according to current, local/national legislation.

Follow the provisions of Directive 2008/98/EC regarding waste management.

SECTION 14: TRANSPORT INFORMATION.

Transport following ADR rules for road transport, RID rules for railway, ADN for inner waterways, IMDG for sea, and ICAO/IATA for air transport.

Land: Transport by road: ADR, Transport by rail: RID.

Transport documentation: Consignment note and written instructions

Sea: Transport by ship: IMDG.

Transport documentation: Bill of lading

Air: Transport by plane: ICAO/IATA.

Transport document: Airway bill.

14.1 UN number or ID number.

UN No:UN3161

14.2 UN proper shipping name.

Description:

ADR/RID:UN 3161, LIQUEFIED GAS, FLAMMABLE, N.O.S. (CONTAINS 2,3,3,3-TETRAFLUOROPROP-1-ENE), 2.1, (B/D)
IMDG:UN 3161, LIQUEFIED GAS, FLAMMABLE, N.O.S. (CONTAINS 2,3,3,3-TETRAFLUOROPROP-1-ENE), 2.1
ICAO/IATA (Passenger aircraft):PROHIBITED
ICAO/IATA (Cargo aircraft):UN 3161, LIQUEFIED GAS, FLAMMABLE, N.O.S. (CONTAINS 2,3,3,3-TETRAFLUOROPROP-1-ENE), 2.1

14.3 Transport hazard class(es).

Class(es):2

14.4 Packing group.

Packing group:Not applicable.

14.5 Environmental hazards.

Marine pollutant:No
Transport by ship, FEm – Emergency sheets (F – Fire, S - Spills):F-D,S-U

14.6 Special precautions for user.

Labels:2.1
ADR 2.1
Hazard number:23
Provisions concerning carriage in bulk ADR:Not authorized carriage in bulk in accordance with ADR.

Proceed in accordance with point 6.

ADR LQ:0
IMDG LQ:0
ICAO LQ:Not applicable.

14.7 Maritime transport in bulk according to IMO instruments.

The product is not transported in bulk.

SECTION 15: REGULATORY INFORMATION.

15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture.

The product is not affected by Regulation (EU) No 528/2012 concerning the making available on the market and use of biocidal products.

The product is not affected by the procedure established Regulation (EU) No 649/2012, concerning the export and import of dangerous chemicals.

15.2 Chemical safety assessment.

No Chemical Safety Assessment has been carried out for this substance/mixture by the supplier.

SECTION 16: OTHER INFORMATION.

Classification codes:

Flam. Gas 1B :Flammable gas, Category 1B
Press. Gas :Gases under pressure, Compressed

Changes regarding to the previous version:

- Changes in the composition of the product (SECTION 3.2).

Classification and procedure used to derive the classification for mixtures according to Regulation (EC) 1272/2008 [CLP]:

Physical hazardsOn basis of test data
Health hazardsCalculation method
Environmental hazardsCalculation method

It is advisable to carry out basic training with regard to health and safety at work in order to handle this product correctly.

Abbreviations and acronyms used:

ADR:Agreement concerning the International Carriage of Dangerous Goods by Road.
CEN:European Committee for Standardization.
PPE:Personal protection equipment.
IATA:International Air Transport Association.
ICAO:International Civil Aviation Organization.
IMDG:International Maritime Code for Dangerous Goods.
RID:Regulations Concerning the International Transport of Dangerous Goods by Rail.

Key literature references and sources for data:

http://eur-lex.europa.eu/homepage.html

http://echa.europa.eu/

Regulation (EU) 2020/878.

Regulation (EC) No 1907/2006.

Regulation (EC) No 1272/2008.

The information given in this Safety Data Sheet has been drafted in accordance with COMMISSION REGULATION (EU) 2020/878 of 18 June 2020 amending Annex II to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemical substances and mixtures (REACH).

The information in this Safety Data Sheet on the Preparation is based on current knowledge and on current EC and national laws, as far as the working conditions of the users is beyond our knowledge and control. The product must not be used for purposes other than those that are specified without first having written instructions on how to handle. It is always the responsibility of the user to take the appropriate measures in order to comply with the requirements established by current legislation. The information contained in this Safety Sheet only states a description of the safety requirements for the preparation, and it must not be considered as a guarantee of its properties.

-End of safety data sheet.-